- Hose Inside Diameter 6mm(1/4")
- Hose Length:12m (40")
- Maximum Pressure:17 bar
- Temperature Range:-5/+65c
- Inlet Connection:1/4BSP
- Outlet Connection:1/4BSP
- KING TOYO KTMTW-F600
- Manufactured from chrome vanadium steel.
- Reversible ratchet head, Micrometer-type sleeve allows accurate - (100-600Ft Lbs) torque values Included case for protective storage
- Length : 1063mm
- KING TOYO KTMTW-F700
- Manufactured from chrome vanadium steel.
- Reversible ratchet head, Micrometer-type sleeve allows accurate - (100-700Ft Lbs) torque values Included case for protective storage
- Length : 1213mm
PRODUCT FEATURES :-
- - Universal application for one car using.
- - Patented design for limited space application, firewall, for example.
- - Easy work to compress valve spring for straight, v-shape engines.
- - Additional pneumatic tools is also available, for save energy working.
- - Sliding main tool help to compress valve spring one cylinder by one cylinder.
- KING TOYO KT-TW6241S
- Square : 3/4"
- Torque : 140-560Nm, 14-57kgf.m, 1200-5000 in lbs, 100-410 ft lbs.
- Lenght : 996mm
- Length independent mechanism • Push through reversible mechanism • Retractable adjustment mechanism avoids accidental adjustment
- Accurate to ±4% •
- KING TOYO KT-TW6242S
- Square : 3/4"
- Torque : 200-800Nm, 22-82kgf.m, 1800-7200 in lbs, 140-600 ft lbs.
- Lenght : 1070mm
- Length independent mechanism
- Push through reversible mechanism
- Retractable adjustment mechanism avoids accidental adjustment
- Accurate to ±4%
- KING TOYO KT-TW3241S
- Square : 3/4"
- Torque : 200-1000Nm, 22-100kgf.m, 1800-8850 in lbs, 140-740 ft lbs.
- Lenght : 1400mm
- Length independent mechanism
- Push through reversible mechanism
- Retractable adjustment mechanism avoids accidental adjustment
- Accurate to ±4% •
- Heavy steel construction, double door on the sides
- Transparent glass viewing window
- 40-80PSI / 15-25CFM)
- Working space: 60x84x63cm
- Overall dimension: 150cm(H)x83cm(L)x63cm(W)
- Electrical requirements of light: 115V/230V
- Maximum operation pressure: 125PSI
Square Drive | 3/4" |
Free Speed | 5500rpm |
Max. Torque | 1100ft-lb (1492N.M) |
Overall Length | 220mm |
Air Inlet | 3/8" |
Air Hose | 1/2" |
Average Air Consumption | 9.5cfm (269L/min) |
Weight | 5.6kg |
Square Drive | 3/4" |
Free Speed | 5500rpm |
Max. Torque | 1100ft-lb (1492N.M) |
Overall Length | 220mm |
Air Inlet | 3/8" |
Air Hose | 1/2" |
Average Air Consumption | 9.5cfm (269L/min) |
Weight | 6kg |
Square Drive | 1" |
Free Speed | 4000rpm |
Max. Torque | 1800ft-lb (2441N.M) |
Overall Length | 282mm |
Air Inlet | 1/2" |
Air Hose | 3/4" |
Average Air Consumption | 12cfm (340L/min) |
Weight | 10.62kg |
Square Drive | 1" |
Free Speed | 3000rpm |
Max. Torque | 2500ft-lb (3390N.M) |
Overall Length | 634mm |
Air Inlet | 1/2" |
Air Hose | 3/4" |
Average Air Consumption | 14.5cfm (411L/min) |
Weight | 16.8kg |
- Side exhaust.
- 9" (229m) Grinder and cutting disc.
- Rated power: 1.49kw.
High Accuracy, High Performance and Reliable Measurements
• 0.09% basic DC accuracy
• Large display with 6,000 counts
• True-RMS Measurements
• Low-pass filter for motor drive measurements
• User calibration function
Safety design for industrial use
• Complies with IEC 61010-1 CAT IV 600V , CAT III 1000V
• Terminal shutter to prevent incorrect test leads' insertion in current terminals
• Very wide operating temperature range from -10 to 55ºC
High Accuracy, High Performance and Reliable Measurements
• 0.09% basic DC accuracy
• Large display with 6,000 counts
• True-RMS Measurements
• True-RMS or MEAN value detection mode can be selected
• Low-pass filter for motor drive measurements
• User calibration function
Safety design for industrial use
• Complies with IEC 61010-1 CAT IV 600V , CAT III 1000V
• Terminal shutter to prevent incorrect test leads' insertion in current terminals
• Very wide operating temperature range from -10 to 55ºC
Reliable support for data management
• Large data internal memory 1,600 data (logging), 100 data (manual)
• Download data and Live Monitoring on a PC via the USB interface
(Option for USB Communication set)
*MAX 32,767 data can be transferred.
High Accuracy, High Performance and Reliable Measurements
• 0.02% basic DC accuracy
• Large display with 50,000 counts
• Dual display for double indication for AC and DC, V and Hz, etc.
• True-RMS Measurements AC and AC+DC
• Fast Peak Hold response time of 250µs
Safety design for industrial use
• Complies with IEC 61010-1 CAT III 1000V, CAT IV 600V
• Terminal shutter to prevent incorrect test leads' insertion in current terminals
• Very wide operating temperature range from -20 to 55ºC
Reliable support for data management
• Large data internal memory
KEW 1061: 1,000 data (logging), 100 data (manual)
• Download data and Live Monitoring on a PC via the USB interface
(Option for USB Communication set)
* MAX 32,767 data can be transferred.
High Accuracy, High Performance and Reliable Measurements
• 0.02% basic DC accuracy
• Large display with 50,000 counts
• Dual display for double indication for AC and DC, V and Hz, etc.
• True-RMS Measurements AC and AC+DC
• Wide AC Frequency bandwidth from 10Hz to 100kHz
• True-RMS or MEAN value detection mode can be selected
• Fast Peak Hold response time of 250µs
• Low-pass filter for motor drive measurements
• Low Power Ω for resistance measurements on sensible electronic circuits by a low and safe test current
• User calibration function
Safety design for industrial use
• Complies with IEC 61010-1 CAT III 1000V, CAT IV 600V
• Terminal shutter to prevent incorrect test leads' insertion in current terminals
• Very wide operating temperature range from -20 to 55ºC
Reliable support for data management
• Large data internal memory
KEW 1062: 10,000 data (logging), 100 data (manual)
• Download data and Live Monitoring on a PC via the USB interface
(Option for USB Communication set)
* MAX 32,767 data can be transferred.
• Can measure large AC current up to 2000A.
• Peak hold function.
• 55mm-dia large tear drop shaped jaws.
• Equipped to measure both AC and DC current with transformer jaws of large diameter.
• Can measure AC and DC currents up to 2000A.
• Output terminal for connection to recorders.
• CAT IV Clamp Meter can measure the Voltage and Current in both very low and high power circuits.
• Accurate True-RMS reading of AC current or voltage with distorted waveform.
• Can measure AC and DC currents up to 2000A.
• Output terminal for connection to recorders.
• High sensitivity, miniature AC/DC clamp meter.
• 0.1mA minimum resolution for AC current and 1mA minimum resolution for DC current.
• Output terminal for recorder connection.
• Smallest clamp meter capable of AC and DC current measurements.
• 300A auto ranging has minimum resolution of 0.01A AC/DC.
• Auto-zero function to allow one touch zero adjustment.
• Designed to meet international safety standard IEC 61010-1 CAT IV 600V.
• CAT IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.
• Very useful for power distribution companies, power utilities and maintenance fields.
• True RMS enables an accurate measurement.
• Flexible and light weight clamp sensor
• Wide reading range up to 3000A
• True RMS
• MIN MAX function
• Backlight LCD display
• IEC 61010-1 (CAT IV 600V / CAT III 1000V)
- Kyoritsu 2412 Leakage Digital Clamp Meter
- • Digital clamp meter with tear drop shaped, medium size transformer jaws specially designed for leakage current measurement.
- • Frequency filter switch to eliminate the effect of harmonics.
- • Output terminal for connection to recorders and facility to operate from external power supply permit continuous leakage current monitoring.
- • Resolution 0.01mA.
• Extra wide transformer jaws are best suited for clamping on all three or four wires (3phases) together for leakage current measurement.
• Frequency filter switch to eliminate the effect of harmonics.
• Output terminal.
• Resolution 0.1mA.
• Large transformer jaws of 68mm diameter makes it possible to clamp on all three or four wires (3 phases) together for leakage current measurement.
• True RMS enables an accurate measurement for distorted waveforms.
• Measurement from mA up to AC 1000A
• Frequency filter switch to eliminate the effect of the harmonics.
• 2 way analogue output terminal
• Resolution 0.1mA
• Frequency Selector Switch to eliminate the effect of harmonics.
• Three AC current ranges 20mA/200mA/200A.
• Rotary switch for easy one finger power-on and range selection.
• Resolution 0.01mA.
• High Sensitive Model
• Frequency Selector Switch to eliminate the effect of harmonics.
• Three AC current ranges:4mA/40mA/100A.
• Resolution 0.001mA
• Frequency Selector Switch to eliminate the effect of harmonics.
• Three AC current ranges:40mA/400mA/400A.
• Resolution 0.01mA.
• Frequency Selector Switch to eliminate the effect of harmonics.
• Three AC current ranges:40mA/400mA/400A.
• Resolution 0.01mA.
• 0.01mA resolution for DC current
• Top class measurement 0.2% accuracy
• Ø6mm clamp jaw easy to use in tight places
• Measurement from 0.01mA to 120.0mA
• Dual display with backlight shows both mA measurement and percent of 4-20 mA span
• Spotlight for illuminating measurement point
• Analog output terminal for recorder connection
• Complies with IEC 61010-1 CAT II 300V
• Bargraph to display insulation resistance.
• Displays the value of external AC voltage along with flashing symbol.
• Auto null function to automatically subtract the test lead resistance before displaying the real continuity resistance value.
• Live circuit warning beeper.
• Releasing the test button automatically discharges the charges stored in the circuit under test.
• 200mA continuity measuring current to IEC 61557.
• Minimum 1mA current on insulation tests to IEC 61557.
• Bargraph to display insulation resistance.
• Displays the value of external AC voltage along with flashing symbol.
• Auto null function to automatically subtract the test lead resistance before displaying the real continuity resistance value.
• Trac-Lok mode to conserve battery life on insulation and continuity tests.
• Live circuit warning beeper.
• Releasing the test button automatically discharges the charges stored in the circuit under test.
• Backlight function to view the test results in dimly lit areas.
• 200mA continuity measuring current to IEC 61557.
• Minimum 1mA current on insulation tests to IEC 61557.
• 3 functions in one unit, insulation test with 4 voltage ranges,
continuity test, AC voltage measurement
• 200mA measuring current on continuity testing
• Comparator function with PASS / FAIL and buzzer
• 0Ω adjustment at continuity measuring range
• Memory function up to 99 data
• Backlight LCD provides easy reading in dark locations
• Safety lock system prevents an erroneous operation
on 500 and 1000 Volt ranges
• Safety standard IEC 61010-01 CAT III 600V
• 3 functions in one unit, insulation test with 4 voltage ranges,
continuity test, AC voltage measurement
• 200mA measuring current on continuity testing
• Comparator function with PASS / FAIL and buzzer
• 0Ω adjustment at continuity measuring range
• Memory function up to 99 data
• Backlight LCD provides easy reading in dark locations
• Safety lock system prevents an erroneous operation
on 500 and 1000 Volt ranges
• Safety standard IEC 61010-01 CAT III 600V
(Photo: 3021)
•3 functions in one unit, insulation test with 4 voltage ranges, continuity test, AC voltage measurement
•200mA measuring current on continuity testing
•Comparator function with PASS / FAIL and buzzer
•0Ω adjustment at continuity measuring range
•Memory function up to 99 data
•Backlight LCD provides easy reading in dark locations
•Safety lock system prevents an erroneous operation on 500 and 1000 Volt ranges
•Safety standard IEC 61010-01 CAT.III 600V
• 3 functions in one unit, insulation test with 4 voltage ranges,
continuity test, AC voltage measurement
• 200mA measuring current on continuity testing
• Comparator function with PASS / FAIL and buzzer
• 0Ω adjustment at continuity measuring range
• Memory function up to 99 data
• Backlight LCD provides easy reading in dark locations
• Safety lock system prevents an erroneous operation
on 500 and 1000 Volt ranges
• Safety standard IEC 61010-01 CAT III 600V
(Photo: 3021)
• Extremely easy and simple operation
• Automatic ranges, indicated by individual LED's
• Newly-designed alligator clip
• It comes with a tough hard case
• Safety Standard IEC 61010-1 CAT IV 300V / CAT III 600V
• Extremely easy and simple operation
• Automatic ranges, indicated by individual LED's
• Newly-designed alligator clip
• It comes with a tough hard case
• Safety Standard IEC 61010-1 CAT IV 300V / CAT III 600V
(Photo: 3121B)
• Rugged design with a hard carrying case for field use
• Detachable High Voltage Line probe
• Automatic ranges, high and low scales, indicated by different LED's
• Drip proof
• Permits a wide range of insulation testing up to 100GΩ at variable test voltage from 1kV to 10kV.
• DC voltage output for recorders.
• Output voltage is shown on the digital display.
• After tests, automatically discharges the charges stored in the circuit under test.
• Operated by rechargeable Nickel-Cadmium batteries.
• Insulation Resistance up to 1TΩ
• Short-Circuit Current up to 1.5mA
• Wide Test Voltage from 250V to 5000V
• Diagnosis Function of PI and DAR
• Newly-designed alligator clip
• It comes with a tough hard case
• Filter function reduces noise interference for obtaining stable measurement
• Large display with Bar Graph indication and backlight
• Live voltage warning
• Safety standard IEC 61010-1 CAT IV 300V / CAT III 600V
• Short-Circuit Current up to 5mA
• Wide range measurements from 500V to 5000V and up to 1TΩ
• Large digital display with Bar Graph indication and white LED back light
• Polarization Index measurement (PI), Dielectric Absorption Ratio (DAR)
• Filter function reduces noise interference for obtaining stable measurement
• Indication of Output voltage and Discharge voltage
• Auto-discharge function and Output voltage warning function
• Auto power off and Battery Indicator
• Safety standard IEC 61010-1 CAT III 600V
• Microprocessor controlled high voltage insulation resistance tester with Diagnostic functions.
• Suitable for analyzing the insulation characteristics of cables, transformers, motors, generators, high-pressure switches, insulators, wiring installations, etc.
• 6 ranges: 500V, 1000V, 2500V, 5000V, 10000V, 12000V
Fine adjustment of voltage setting at each range is also possible
• Graphic representation of the insulation resistance and leakage current versus time on large display with bar graph and backlight.
• Can be operated from built-in rechargeable battery or from AC line.
• Automatic discharge after test with monitoring of the discharge voltage.
• Internal memory can store about 43,000 data (max).
• Robust design for field use with IP64 rating (with lid closed).
The Model 3131A offers unmatched performance, and feature including test lead resistance zero adjustment for time-saving continuous operation, a clear ease to read illuminated scale, and a live circuit warning.
• Test insulation up to 100MΩ at 250V, 200MΩ at 500V, 400MΩ at 1000V and continuity up to 20Ω.
• LIVE circuit warning lamp plus audible warning.
• Automatic discharge of circuit capacitance when TEST button is released.
• Fuse protected (continuity range only).
• Battery check LED.
• Front panel zero adjust.
• Back light function to facilitate working at dimly lit situations.
• PRESS TO TEST button with lock down feature.
Analogue Insulation / Continuity Tester
• Miniature lightweight insulation tester. It weighs only 340g(battery included),
but carries full measurement functions.
• Automatic discharge of circuit capacitance.
• Test leads with remote control switch.
• New robust housing case.
• Back light function.
• Neck strap for both hands operation
• The latest circuit design permits the instrument to operate
with the minimum of influence from earth voltage
and earth resistance of auxiliary earth spikes.
• Dust and drip proof. (designed to IEC 529 IP54)
• Earth resistance value can be read directly from the scale.
• Designed to meet IEC 61010-1 safety standard.
• Capable of measuring earth voltage.
• Small and lightweight. Shock resistant new case material.
• 2mA measuring current permits earth resistance tests
without tripping earth leakage current breakers
in the circuit under test.
• Lead wire connection to C and P terminals and proper
auxiliary earth resistance can be checked by "OK" lamp.
Lead wire connection to C and E terminals is good
when "OK" lamp is illuminated.
4102A-H Hard Case Model
• The latest circuit design permits the instrument to operate
with the minimum of influence from earth voltage
and earth resistance of auxiliary earth spikes.
• Dust and drip proof. (designed to IEC 529 IP54)
• Earth resistance value can be read directly from the scale.
• Designed to meet IEC 61010-1 safety standard.
• Capable of measuring earth voltage.
• Small and lightweight. Shock resistant new case material.
• 2mA measuring current permits earth resistance tests
without tripping earth leakage current breakers
in the circuit under test.
• Lead wire connection to C and P terminals and proper
auxiliary earth resistance can be checked by "OK" lamp.
Lead wire connection to C and E terminals is good
when "OK" lamp is illuminated.
Earth Resistance & Resistivity Tester
• High test current up to 80mA yielding resolution of 0.001Ω on 2Ω range.
• Advanced Filtering method (based on FFT Fast Fourier Transform) reduces noise interference for obtaining stable measurements.
• Automatic and Manual selection of the Test Current Frequency in four bands (94/105/111/128Hz). In Automatic mode, KEW 4106 will select the most suitable Frequency.
• Several sub-results can be shown on the display: Resistance of the Auxiliary Earth Spikes, Frequency of Test Current, Voltage and Frequency of Interference (noise), Residual Resistance Rk, etc.
• Warning for excessive noise and high Auxiliary Earth Spikes resistance.
• Large Graphic Display with backlight for readings in poorly illuminated areas.
• Up to 800 measurement results can be saved in the memory and recalled on the display.
• The stored results can be transferred to a PC using the "KEW Report" software and a USB adaptor (Model 8212-USB) which are included.
• Robust design with IP54 protection.